Release Date: 18-Sep-2008
Document Last Updated: 18-Sep-2008
Download Size: 48MB Download Filename: ESX350-200808402-BG.zip md5sum: efa7650b8780332d900615409db50254
| | Product Versions | ESX 3.5 | | Patch Classification | Critical | | Supersedes | ESX350-200712407-BG ESX350-200802409-BG ESX350-200803211-UG ESX350-200804407-BG ESX350-200805503-BG ESX350-200806402-BG | | Requires | ESX350-200808201-UG ESX350-200808408-BG | | Virtual Machine Migration or Shutdown Required | Yes | | Host Reboot Required | Yes | | PRs Fixed | 232643, 242571, 275088 | | Affected Hardware | | | Affected Software | N/A | | RPMs Included | kernel-source kernel-vmnix | | Related CVE numbers | None |
|
Summaries and Symptoms
Issues fixed in this patch (and their relevant symptoms, if applicable) include:
- On ESX hosts with more than one CD-ROM device, rescanning storage (vmhba) causes the host to crash with a purple screen that displays CosPanic:4781: COS Error: Oops.
- The root disk goes offline and the ESX service console becomes read-only during long cluster failovers on storage arrays. This issue applies to both Active/Active and Active/Passive storage arrays.
- Includes a fix to better support Broadcom RemotePHY backplanes on Dell PowerEdge blade servers.
Deployment Considerations
ESX350-200808402-BG requires the installation of ESX 3.5 U2 refresh bundle ESX350-200808201-UG, irrespective of whether the ESX 3.5 U2 hot fix bundle ESX350-200806812-BG is currently installed or not. Make sure that ESX 3.5 U2 refresh bundle ESX350-200808201-UG is available in the local depot before installation.
If you are using esxupdate , you must install 2nd-level dependencies before installing this patch.
Based on VMware KB 1005808